Wednesday, October 17, 2012

Optimizing your Plant and save on Energy

Its an observed fact that ( i.e. Fluid Handling System )
During plant operation there is a waste of energy due to following
  1. Wrong selection on Type of  Pumpset.
  2. Oversize Pumpset Selection.
  3. Wrong estimation of System Pressure 
  4. Pipeline Loss. 
  5. Trying to push up with old out dated equipment.
  6. Motor repair and rewinding 
  7. Using less efficiency equipment  due to low initial cost.
  8. Never considering Life-Cycle-Cost of Equipment 
  9. Throttling Loss not known.
  10. Application Engineering  never consider  
  11. Pre - Maintenance Activities never carried out.  
  12. Old Plant never undergone upgrading. 

We make sure all most all the activities are carried our with support, advice and discussion with the maintenance manager.

Give us a call and we will study your plant for upgrade ( if required ) on Fluid Handling System.

91-99677870808 ( Bhalchandra Padwal )


Diaphragm pumps vs. Peristaltic metering pumps. i

Hello guys


If you are currently using diaphragm pumps in your work and having success the odds are good you are educated on the basics of maintaining your diaphragm pump. I’m also pretty sure the more you learned, the more successful your pumps were…right? Although today’s diaphragm pumps are more sophisticated, better valves, diaphragms, drive mech- anisms, etc. than years ago; they still require a basic understanding for a successful program. Peristaltic pumps on the other hand are initially simpler to use, and require less experience to operate under adverse conditions. This is where we begin:

Diaphragm metering pumps –

Pros
1. Well maintained a diaphragm metering pump cost you less to operate over time.
2. Diaphragm metering pumps are more energy (power) stroke, but far less on the back stroke.
3. Overcoming line pressure is easier with properly sized diaphragm metering pumps.
4. Less danger of leakage - Poorly maintained,  diaphragm metering pump way lose its prime, but seldom leaks, or damages area.

Cons
1. Solution being pumped needs to be clean - diaphragm metering pumps operate best when the solution being pumped is clean, free from particulates. The reason; diaphragm metering pumps have check valves in the suction and discharge side of the pump head. If either set of check valves prime will occur
pumps Prime best when there is little to no back valve to aid in this challenge. phragm pumps prime best when the valves (check balls) are clean and there is little to no back pressure, and the diaphragm stroke is on full or maximum setting. adjustment) is on a low setting. Most diaphragm metering pumps has a diaphragm stroke (feed rate) adjustment, and some also have a motor speed adjustment. Priming is best achieved when the
stroke adjustment is above the 60% area. These adjustments can be confusing, try to minimize your variables as much as possible. Avoid adjusting the diaphragm stroke length to low, the pump loses ef-longer stroke lengths. Insummary (diaphragm metering pump) will require you to be a bit more knowledgeable about


Tuesday, June 12, 2012

Pump Opitimization in Details.mp4


Bhalchandra Padwal
Business Development Manager
+91 9967787080 / 9820108724 / 9029682381
 MM 59 4/4 B/H Siddivinayak Stores, Khadev Nagar
Chembur Govindi Road, Chembur, Mumbai - 400071 INDIA
Skype ID : optimizesolution

Pump Opitimization in Details.mp4

Hi

See our optimization work in details.

Regards


Bhalchandra Padwal

Saturday, June 9, 2012

Pump in Biogas.mp4



Pumps for biogas plant


Bhalchandra Padwal
Business Development Manager
+91 9967787080 / 9820108724 / 9029682381
 MM 59 4/4 B/H Siddivinayak Stores, Khadev Nagar
Chembur Govindi Road, Chembur, Mumbai - 400071 INDIA
Skype ID : optimizesolution

Optimize Solution Complete Presentation.mp4



Complete service of OPTIMIZE SOLUTION

Thursday, May 31, 2012

Installation and commissioning of centrifugal pump.mp4

Hi

How to Install a Centrifugal Pump for Low Maintenance and High Service Life? Watch





Bhalchandra Padwal
Business Development Manager
+91 9967787080 / 9820108724 / 9029682381
MM 59 4/4 B/H Siddivinayak Stores, Khadev Nagar
Chembur Govindi Road, Chembur, Mumbai - 400071 INDIA
Skype ID : optimizesolution

Thursday, March 1, 2012

Optimize Solution - Environmental Pump



Please visit our website for more details on pumps


Bhalchandra Padwal
Business Development Manager
091 9967787080
optimizesolution@live.com
www.optimizesolution.vze.com
MM 59 4/4 B/H Siddivinayak Stores, Khadev Nagar
Chembur Govindi Road, Chembur, Mumbai - 400071 INDIA
www.optimizesolution.blogspot.com
Skype ID : optimizesolution
MSN ID : optimizesolution@live.com

Tuesday, February 28, 2012

Sunday, February 5, 2012

Friday, January 20, 2012

Energy Efficient Drive Technology - Siemens

Watchout Energy Saving Drive Technology Posted by Siemens for General Idea.

This video gives you of automation saving on electrical side. We help you to save energy on mechanical equipment like pump, mechanical seal, reduction drive, and pipeline losses (i.e. throttling valve losses, By-pass line losses, undersize pipeline losses, oversize or undersize pump losses, use of pony pump and energy efficeient motors etc... ) .